Local Law 88: the lighting and sub-metering deadline that already passed

Local Law 88 is two separate requirements wearing one number, and for a residential co-op or condo most of it probably does not apply. The deadline for both was January 1, 2025, so if your board has never looked at this, the question is not whether you are ready. It is whether you owed anything in the first place.
The two halves are a lighting upgrade and a sub-meter installation. Work through the four questions below and you will know where your building stands in about ten minutes.
Question 1: is your building covered?
Measured on the Department of Finance record:
- A building that exceeds 25,000 gross square feet
- Two or more buildings on the same tax lot that together exceed 100,000 gross square feet
- Two or more buildings held in condominium form, governed by the same board of managers, that together exceed 100,000 gross square feet
Two kinds of property are excluded outright. One, two or three family homes and property classified as Tax Class 1. And garden style apartments, defined as a series of attached, detached or semi-detached dwellings no more than three stories, where each owner holds responsibility for their own HVAC and hot water systems and no system serves more than two dwelling units, certified by a registered design professional.
If you are below the threshold or inside an exclusion, you are done. Everything below is for buildings that are covered.
Question 2: the lighting half, and what a co-op actually owes
By January 1, 2025, lighting systems in covered buildings had to meet the standards for new systems set out in the New York City Energy Conservation Code as of the date of installation.
Here is the line that changes the answer for most residential boards: no lighting system upgrade or sub-meter installation is required for dwelling units classified in occupancy group R-2 or R-3.
Apartments in a residential co-op or condo are R-2. So the lighting obligation does not reach inside anyone’s apartment. What it does reach is everything else: the lobby, the corridors, the stairwells, the laundry room, the boiler room, the basement, the garage, the exterior.
Two further carve-outs narrow it again. No upgrade is required for an element of a lighting system that already meets the energy code standards in effect for new systems installed on or after July 1, 2010. And no upgrade is required for lighting power densities in a space bounded by permanent floor to ceiling partitions or closable doors that already meet those standards.
So a building that relamped its common areas to LED with modern controls at some point in the last fifteen years may owe nothing but the paperwork confirming it.
Question 3: the sub-metering half, and whether you have a covered tenant space
On and after January 1, 2025, the electrical use of each covered tenant space has to be measured by one or more sub-meters, with monthly statements provided to the tenant.
A covered tenant space is one of two things:
- A tenant space larger than 5,000 gross square feet, on one or more floors, let or sublet to the same person
- A floor larger than 5,000 gross square feet made up of tenant spaces let or sublet to two or more different people
Again, R-2 and R-3 dwelling units are out. So the apartments are not covered tenant spaces, and in a purely residential building the answer here is usually that you have none.
Where it bites is commercial space. A prewar co-op with a 6,000 square foot medical office, a supermarket, or a bank branch on the ground floor has a covered tenant space and owes a sub-meter and monthly statements. A co-op with three small storefronts of 1,200 square feet each does not, unless they sit on a floor that totals more than 5,000 square feet of tenant space.
One more exclusion worth knowing: no sub-meter is required for a covered tenant space whose electrical consumption is already measured by a meter dedicated exclusively to that space. A commercial tenant on its own direct Con Edison meter is already satisfying the point of the rule.
Question 4: has your building filed?
This is where boards who did the physical work still fail.
Reports were due May 1, 2025, filed through the BEAM platform, with a $115 filing fee covering both the lighting and sub-metering reports. For buildings that were filing a Local Law 97 report in 2025, there was no additional filing fee. Buildings that filed a compliance plan by December 31, 2025 had until May 1, 2026 to file a compliant report.
The report is an attestation. For lighting, it certifies that the lighting system of the entire building has been inspected and upgrades implemented. For sub-metering, it certifies that sub-meters have been installed for all covered tenant spaces, and it includes a list of those spaces and a sample monthly statement.
The attestation has to come from a registered design professional, or a licensed master or special electrician, certifying that the work complies with the technical standards of the energy code. Your super cannot sign it and neither can your managing agent.
The 2026 Covered Buildings List only lists buildings that have not yet demonstrated compliance. If your building appears on it, that is the Department telling you it has no record of your filing.
What to do if you are late
Both deadlines have passed, so a board discovering this now is behind rather than preparing. The sequence that gets you current fastest:
- Check the 2026 Covered Buildings List for your BBL. If you are not on it, the Department already has your compliance on record.
- If you are on it, work out which halves you actually owe using questions 2 and 3. For most residential buildings this is common area lighting only.
- Get a registered design professional or licensed electrician to inspect the common area lighting against the energy code. In a building that has already moved to LED, this may be a confirmation rather than a project.
- File through BEAM with the attestation.
Our view is that step 2 is where boards waste the most money. A board that hires a consultant before working out that its apartments and its three small storefronts are all outside the law ends up paying to be told so.
Where this sits against the other energy laws
Local Law 88 is the only one of the four that is a one-time obligation rather than a recurring cycle. Benchmarking under Local Law 84 is every year. The Local Law 87 audit is every ten years. Local Law 97 reporting is every year with limits that tighten in 2030. Local Law 88 you do once, file once, and are finished.
That is worth saying because it changes how a board should treat the cost. This is not an annual line item. It is a one-off, and on a residential building with LED common areas it may be a very small one.
How we handle it
We manage 35 buildings and about 2,000 units across Manhattan, Queens and Brooklyn, 27 cooperatives and five condominiums. The first thing we do on a new building is pull its filing history across every program, which is how a gap like an unfiled Local Law 88 report surfaces before it becomes a violation rather than after.
The three things boards ask us about are who is behind on maintenance, what is in the accounts, and what is on the agenda. A one-time energy filing from 2025 is exactly the kind of thing that falls between those questions, and exactly the kind of thing a managing agent should be carrying.
Talk to us about your building
Tell us your square footage and whether you have commercial space on the ground floor, and we will tell you which half of this you owe.
Tell us about your building or schedule a meeting.
For the annual filings rather than the one-time one, read Local Law 84 benchmarking and the Local Law 97 post. Local Law 87 energy audits covers the ten-year cycle. Our guide to the NYC local laws puts the whole calendar on one page.
Frequently asked questions
Does Local Law 88 require us to replace lighting inside apartments?
No. Dwelling units in occupancy group R-2 or R-3 are excluded from both the lighting upgrade and the sub-meter requirement, so the obligation stops at the apartment door. Common areas, back of house spaces and the garage are what the law reaches in a residential building.
What counts as a covered tenant space?
A space larger than 5,000 gross square feet let or sublet to the same person, or a floor larger than 5,000 gross square feet made up of spaces let to two or more different people. Residential dwelling units are excluded, so in practice this means commercial tenants.
Our commercial tenant has its own Con Edison meter. Do we still need a sub-meter?
No. A covered tenant space whose electrical consumption is already measured by a meter dedicated exclusively to that space does not require a sub-meter installation.
Who signs the Local Law 88 report?
A registered design professional, or a licensed master or special electrician, certifying that the upgrade or installation is complete and complies with the technical standards of the New York City Energy Conservation Code.
We are on the 2026 Covered Buildings List. Does that mean we failed?
It means the Department has no record of your compliance. The 2026 list only includes buildings that have not yet demonstrated it, so a building already in compliance that still appears on the list should check its filing record rather than redo the work.
Is this an annual filing?
No. Local Law 88 is a one-time obligation, unlike benchmarking and the Local Law 97 report, which are annual, and the Local Law 87 energy audit, which runs on a ten-year cycle.