Local Law 84 benchmarking: what your board gets for the May 1 filing

Local Law 84 requires New York City buildings over 25,000 square feet to report their energy and water use to the city every year by May 1. The reporting runs through the Environmental Protection Agency’s Energy Star Portfolio Manager. It is the cheapest filing on your compliance calendar and the one boards get the least out of.
That is the part worth fixing. Benchmarking is not just a form. It produces a number that tells your board whether the building is running well or badly against similar buildings nationwide, and almost nobody reads it.
So rather than restate the rules, this walks one building through what the filing produces and what a board should do with it.
First, whether you are covered
Four categories, measured on the Department of Finance record:
- A building over 25,000 gross square feet
- Two or more buildings on the same tax lot that together exceed 100,000 gross square feet
- Two or more buildings held in condominium form, governed by the same board of managers, that together exceed 100,000 gross square feet
- A City building
Three kinds of property are excluded: city buildings in the tenant interim lease apartment purchase program, property classified as Tax Class 1, which is most one to three family homes, and garden style apartments certified as such by a registered design professional.
Your status can change from year to year, which is the trap. A new Covered Buildings List goes up every February, and the Department of Finance notes the requirement on your property tax bill the previous November. A board that checked once in 2023 and concluded it was exempt may be wrong now.
The worked example: a 70,000 square foot prewar co-op
Here is a simple example. Say a 1928 elevator co-op in upper Manhattan, 70,000 square feet, 84 units, gas heat and hot water, one commercial tenant on the ground floor.
What the board does in the spring. Somebody collects whole building energy data from Con Edison. The building is flagged for water, so water data is requested from the Department of Environmental Protection too. All of it goes into Energy Star Portfolio Manager, along with the building’s characteristics and its borough, block and lot number and Building Identification Number, both mandatory fields. The property is then shared with the City through the tool. That is the filing.
What comes back. Portfolio Manager scores the building against similar properties nationwide using its property type. The board now has a number, and the number is comparable, which is the whole point of the law.
What the board usually does with it. Files it and moves on.
What the board should do with it. Three things.
First, look at the trend rather than the score. One year’s number tells you very little, because weather varies and a cold winter moves the figure. Three years in the same direction is information. A building whose energy use per square foot has climbed three years running has something wrong that nobody has noticed, and it is usually controls, a failed sensor, or a change in how the building is being used.
Second, compare the energy figure against the Local Law 97 limit. Benchmarking data is the raw material for the carbon calculation, and the city itself used benchmarking data to set the first compliance period’s limits. A board that is reading its benchmarking trend is already most of the way to knowing whether it has a 2030 problem.
Third, read the water line. Water is the number boards ignore completely, and in a prewar building with original fixtures and a commercial tenant it is often the cheapest thing on the whole list to fix.
Why this filing is worth doing properly rather than quickly
The temptation is to treat benchmarking as a box, because the penalty for a bad number is nothing. There is no benchmarking limit to breach. You can file the worst score in the borough and the city will accept it.
But the same data feeds the Local Law 97 report, the energy grade posted at your entrance, and any serious conversation with an engineer about what to replace. Garbage in one year produces three wrong conclusions later.
The most common data problem is not laziness, it is utility data. The Department has previously issued notices confirming that properties hit by utility data errors would not receive violations for missing the deadline. If the numbers coming out of Portfolio Manager look impossible, check the utility feed before you check the building.
When the deadline moves
May 1 is the rule, and the city has moved it more than once. The 2025 deadline was extended to June 30, 2025. An earlier cycle was extended from February 1 to February 21, 2024.
Treat the extensions as luck rather than as a plan. The practical approach is to have the utility data pulled in March, which leaves room for the data problems that actually cause late filings.
Who does the work
Building owners can assign a representative to work with the building staff on the submission, which in practice means the managing agent assembles the data and files, with the super pulling meter information.
Unlike the Local Law 87 report or the Local Law 97 report, benchmarking does not require a registered design professional to certify it. That is why it is cheap, and also why it is the filing most likely to be done carelessly.
Where this does not apply
A 20,000 square foot walkup on its own tax lot does not benchmark. Neither does a Tax Class 1 property, which covers most one to three family homes. Garden style apartment complexes can be excluded, but that one needs a registered design professional to certify it rather than a board’s own judgment.
If you are below the threshold, the useful thing is not a filing. It is reading your own Con Edison bills year over year, which gives you most of the same signal for free.
How we handle it
We manage 35 buildings and about 2,000 units across Manhattan, Queens and Brooklyn, 27 of them cooperatives. Benchmarking sits on the same compliance calendar as everything else, planned a year ahead and visible to the board in its portal, with the utility data pulled early enough that a bad feed is a March problem rather than an April emergency.
Boards call us about who is behind on maintenance, what is in the accounts, and what is on the agenda. A benchmarking score has never once been the reason a board picked up the phone, which is precisely why it is our job to read it and bring it to them.
Talk to us about your building
Tell us the square footage and the borough and we will tell you what you owe and when.
Tell us about your building or schedule a meeting.
Benchmarking feeds the laws with teeth. Read the Local Law 97 post for the carbon limit this data is measured against, Local Law 87 energy audits for the ten-year audit cycle, and Local Law 88 for the one-time lighting and sub-metering filing whose deadline has already passed. Our guide to the NYC local laws shows how all of it overlaps in one year.
Frequently asked questions
What is the Local Law 84 deadline?
May 1 every year, covering the previous calendar year’s energy and water use. The city has extended it more than once, including to June 30 in 2025, but the extension is announced by service notice and cannot be planned around.
Does our co-op need a professional to file benchmarking?
No. Unlike the Local Law 87 and Local Law 97 reports, benchmarking does not require a registered design professional. An owner can assign a representative, which usually means the managing agent, working with building staff to collect the meter data.
What happens if we file a bad score?
Nothing directly. There is no minimum score and no penalty for a poor result. The penalty exists for not filing, not for the number. The reason to care about the number is that it feeds the carbon limit, the energy grade at your door, and any engineering decision you make later.
Do we have to report water as well as energy?
Only if your property is flagged for it on the Covered Buildings List, in the column showing whether water data is required from the Department of Environmental Protection. If it is flagged, the water data has to be requested from DEP and included.
We were exempt last year. Are we still exempt?
Check again. A property’s status can change from year to year, a new Covered Buildings List goes up every February, and the requirement is noted on your property tax bill the previous November. Boards get caught by assuming last year’s answer still holds.
How does benchmarking relate to Local Law 97?
It is the measurement layer underneath it. Benchmarking reports how much energy the building uses; Local Law 97 converts energy use into carbon and compares it to a limit. The city used benchmarking data to design the first compliance period, which is why a board watching its benchmarking trend already knows roughly where it stands.
More Articles
Local Law 88: the lighting and sub-metering deadline that already passed